Big, Small and In Between. Nordyne M7RL Series Downflow 4 Tons Gas 1/2 hp Furnace www.ferguson.com LEAD LAW WARNING: In accordance with the US Federal or other States laws It is illegal to install products that are not “lead free” certified in potable water systems anticipated for human consumption. Visit our HEATING AND AIR CONDITIONING page for other related blog posts on this subject, or go to the INDEX for a complete listing of all our articles. It averages around five times the RLA. Intertherm/Nordyne is the no 1 Seller of Mobile and Modular Home Furnaces in America! We also have installation guides, diagrams and manuals to help you along the way! Just like the nominal size of lumber or an air conditioning filter, the exact cooling capacity may be a little more or less than the nominal rating, but it’s close. The following list equates nominal cooling tonnage to model numbers. 0000000016 00000 n 19 0 obj<> endobj We heat, cool and condition the air in manufactured homes, million-dollar mansions and massive commercial structures. We have manuals, guides and of course parts for common MGBB 056ABFC-06 problems. Find out more about this commercial brand. Split system air conditioner - Single & 3 phase, r-22 4-5 TON SERIES - FOR EXPORT ONLY 10 SEER. For Nordyne, you should look for the two numbers in the second cluster of digits of the model number, which will be divisible by 6 or 12, and represents the nominal BTU of the system in thousands. The digits you need. This discontinued product, which had been manufactured by Nordyne, was available with cooling capacities ranging from 23,600 to 54,000 BTU/H, depending on the individual model. What's wrong? It is commonly found in the first three digits – sometimes and Btus, sometimes as tons. How many tons is Ameristar air conditioner or heat pump? Nordyne MS3QA048KA central air conditioner parts - manufacturer-approved parts for a proper fit every time! In the case of this Lennox model (which, by the way, is not from the outdoor unit shown at the top of this article), the 13HPX tells you it's a heat pump with an efficiency rating of 13 SEER. At Nortek Global HVAC, we manufacture heating and air systems for just about every application you can imagine. Convert the kilowatt rating of your heat pump to British thermal units (BTUs). What is wrong with an air conditioner when the air flow out of the vents is low? By gathering a little more information, you might be able to find the actual capacity of your air conditioner. 0000001035 00000 n • How can I find out the size of my air conditioner? Multiply the kilowatt rating by 3,414.45, the number of BTUs in a kilowatt. ; GMP075-3 (75,000 bonnet input) Compressor is same: serial # 9709088872 (yr1997 wk 09) Tonnage is model # CK361C The first two numbers after the CK (letters) divided by 12 is tons. To help you look up your part number by model number. (Note: Tonnage, Air Flow, kW, etc. Nordyne® How to determine the date of production/manufacture or age of Nordyne® HVAC Systems. MODEL IDENTIFICATION CODE C6 Indoor Coils Figure 1. Btu rating is model number..i.e. It’s not an exact science, but understanding tonnage designations provides an educated guess when working with unfamiliar model numbers. Why does it take so long to cool a house when an air conditioner has been off for a while? My air conditioner won't turn on. The Model # is CR42K6E-PFV-875.TECHNICAL SPECIFICATIONS.Tonnage:3-1/2 to 4 Ton Depending on... See Details AC Condenser Compressor 4 5 Ton Fits Nordyne Intertherm Miller 922180 9221800 %PDF-1.5 %���� At Nortek Global HVAC, we address your light commercial needs with Mammoth Light Commercial. • Why is my air conditioner not cooling enough? The fifth number is for unit's Seasonal Energy Efficiency Ratio. : 36 div by 12= 3 A ton of air conditioning equals 12,000 BTU, and 48 divided by 12 equals 4, so the data plate below indicates the system is 4 tons. xref ... E2EB012HB Nordyne Electric Furnace Parts. The fourth letter equals the product family. (2) Hover over each grouping to reveal pertinent info for each part of the model number. This furnace is model E4EB-015H which is the replacement for old Models E1EB-015HA & E2EB-015HA. • My air conditioner won't turn on. are located within the oval/round shaped buttons). Check your existing furnace to see how many KWs you require! • How can I find out the age of my air conditioner or furnace? Where is the air filter for my central air conditioner and furnace? To learn more about heating and air conditioning systems, see these other blog posts: • How can I find out the SEER of my air conditioner? Why is my air conditioner not cooling enough? If you divide the RLA by 6 for older units and 5 or 6 for newer units, you should get a number that approximates (not exactly) the tonnage of the system. How can I tell whether the condenser (outdoor unit) is an air conditioner or heat pump? • What are the most common problems with wall/window air conditioners? trailer 0000003649 00000 n • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •. How can I find out the size of my air conditioner? Hi, Could you please tell me the tonnage for a York Rooftop unit Model BP090C00N2AAH41 Serial number N0K7293660 Thank you! If you don’t want to do the math, here are the numbers you’re looking for and their corresponding tonnage: 18 = 1.5 tons. H3 Series Unit Nomenclature. 0000003400 00000 n • Will closing doors reduce my heating and cooling costs? In the first method, you find the nominal size by looking at the model number of the outdoor unit. • What is wrong with an air conditioner when the air flow out of the vents is low? Sort by. Cased Coil Wrapper SKU Cabinet Identifier Overall Width Overall Height Liquid Line Height Suction Line Height Opening Width W H HL HS OW 920256 A 14 1/4" 20 3/4" 17 1/2" 15 1/2" 12 7/8" 920257 A 14 1/4" 26 3/4" 23 1/2" 21 1/2" 12 7/8" Find all the parts you need for your Nordyne Central Air Conditioner S3QA-042K at RepairClinic.com. What you need is the model number of the indoor coil, which is the evaporator coil for an air conditioner or heat pump in cooling mode. model number identification serial number identification c p l t 48 x 03 10 xxxxxxxx condensing unit year of mfg month of mfg btu (thousands) sequential number revision style heat pump e-10 seer j-12 seer t-13 seer. If your system happens to not have the BTU or the tons information listed, locate the model number on the label. 19 11 • Why has the thermostat screen gone blank? For Nordyne, you should look for the two numbers in the second cluster of digits of the model number, which will be divisible by 6 or 12, and represents the nominal BTU of the system in thousands. i.e. Below are examples of how the BTU equivalent of a unit is often portrayed and incorporated into a model number; Trane Unit YCD180F – The actual BTU for this unit is 180,000, but is truncated down to 180. Model Input A B C Weights Number (Btuh) inches inches inches (lbs) G6RK060C-12 60,000 14 1/4 12 3/4 5 1/2 105 G6RK072C-12 72,000 14 1/4 12 3/4 5 1/2 115 G6RK072C-16 72,000 19 3/4 18 1/4 11 130 G6RK096C-12 96,000 19 3/4 18 1/4 11 150 G6RK096C-16 96,000 19 3/4 18 1/4 11 158 Does an old air conditioner use more electricity as it ages? Hi, Could you please tell me the tonnage for a York Rooftop. You can determine the “nominal” condenser tonnage of your HVAC system by examining the model number on the data plate at the side of the condenser (outdoor unit). Description Part Number Blower, 2-3 ton 903773 Blower, 2-4 Ton 903413 Blower, 2-5 Ton 903414 Relay Kit, 2 wire 903092A Relay Kit, 4-7 wire 903098A Heating Thermostat (I) 903182 / 903188 Heating Thermostat (M) 903183 / 903189 First letter: The model number starts with 4. Second letter. The Intertherm S3QA air conditioner is a 10 SEER split-system unit designed for manufactured homes. 24 = 2 tons. <<00a5e8b9cc9d584996a459e97b65397d>]>> How can I find out the age of my air conditioner or furnace? We are in Florida and provide plenty of information about hurricanes and sinkholes, for example, but nothing on basements and ice dams. The seven and eight number indicate tonnage. 0000000705 00000 n View & download of more than 1078 Nordyne PDF user manuals, service manuals, operating guides. MODEL IDENTIFICATION CODES EX: T3BA-036K T 3 B A - 036 K Nominal Capacity (000) BTU Electrical Code C = 208/230-60-3 K = 208/230-60-1 S - Air Conditioner T - Heat Pump Generation 1, 2, 3. etc. Here we host technical specifications, wiring diagrams, installation instructions and more. All products. For Ameristar, you should look for right two numbers in the cluster of four numbers in the middle of the model number They are divisible by 6 or 12, and represent the nominal BTU of the system in thousands. Table 7.2.11 Nordyne Model Number Description G 6 R A 144 C 20 C Furnace Fuel Type Design Series Furnace Type Furnace Configuration Heating Input (btu/h) Certification Type Nominal CFM Cabinet Width G, FG, KG, L = Gas 6 or 1 R = Residential T = Residential, two-stage A = Upflow C = Upflow, Condensing K = Downflow L = Downflow, • Why does it take so long to cool a house when an air conditioner has been off for a while? Locate Your Evaporator Coil Model and Serial Numbers. To determine the age of a Nordyne system, go to our blog post How can I tell the age of a Nordyne air conditioner from the serial number? Make sure you use RLA and not LRA, Locked Rotor Amperage, which is the surge of amps necessary to overcome inertia and start the system. endstream endobj 20 0 obj<> endobj 21 0 obj<> endobj 23 0 obj<>/ProcSet 29 0 R>>>> endobj 24 0 obj<> endobj 25 0 obj<> endobj 26 0 obj<> endobj 27 0 obj<> endobj 28 0 obj<>stream A ton of air conditioning equals 12,000 BTU, and 36 divided by 12 equals 3, so the data plate below indicates the system is 3 tons. We are not affiliated with, and do not receive any compensation from, any of the companies or products mentioned in this blog. • How can I tell whether the condenser (outdoor unit) is an air conditioner or heat pump? The first section in the model number gives you info about the type and efficiency of the unit you're looking at. • Does an old air conditioner use more electricity as it ages? >>. How can I find out the SEER of my air conditioner? Access Our Technical Literature. A ton of air conditioning equals 12,000 BTU, and 36 divided by 12 equals 3, so the data plate below indicates the system is 3 tons. 22 0 obj<>stream x�b```��_��(�������a���}���b`89c�aZ��& �f �G�P�� ��-\ ���gD�����!6����� v�� ';� Contact a local Heating, Ventilating and Air Conditioning (HVAC) contractor and provide them with the model number. Functional Cookies help us personalize your shopping experience! information in the model number. I can’t find it? • How did homes stay cool in Florida before air conditioning? We have manuals, guides and of course parts for common S3QA-042K problems. 0000000804 00000 n Divide the result by 12,000, the number of BTUs in a ton. Will closing doors reduce my heating and cooling costs? This How-To shows you the Search By Model Number. Divide the number by 12 (which represents 12,000 Btu/hr, or one ton of cooling capacity) to get your AC unit’s tonnage. How did homes stay cool in Florida before air conditioning? Ducane Heat Pump Model Number 4HP16B24P-2A (Made up model number) 4 is R410a Refrigerant HP is Heat Pump 16 is SEER rating of the Heat Pump B is Wire Guard or it has: L = Louvered LT = Louvered Two Stage 24 is capacity. For example, a 5-kw heat pump has 17,072 BTUs. The date of production/manufacture or age of Nordyne® HVAC equipment can be determined from the serial number located on the data plate. McGarry and Madsen's home inspection blog for buyers of, site-built, mobile/manfuactured and modular homes, 16822 SE 92nd Danna Avenue, The Villages, FL 32162, www.thevillagesbestinspector.com • Comments or questions to  mcgarryandmadsen@mac.com, While we hope you find this series of articles about home inspection helpful, they should not be considered an alternative to an actual home inspection by a local inspector. Click here to view a parts listing for the E2EB012HB which includes partial wiring diagrams that we currently have available. Qq܋�۩�x k���j]�(rו�H�|U��*I�1�1i7=l�cC?h�WJ�>̈́(%�_�����tF��Mf��\�5���0���2��CCr ǡ���$������XU�\�x�. Dividing the BTUs by 12,000 yields 1.42 tons. 0000002093 00000 n startxref H�Ֆώ�0Ɵ�w�c{����HYEJH��=��ni7�r�j��5�TlJ�"UMr�D�����cOR���?H#�@��`��'�$a�/�^��wx�Yh��!�b��w,t���: JmW����p���h�d ���h��0���i���X��x�n9�7�f0�<0Y�)�����J�؋�6���dou���i�6Ar���:F+e�4{z)��h�C ݘ��U�&:d/��� 0000000516 00000 n << What are the basic facts about sinkholes? If you are unsure whether you have found the right two numbers, you can double-check it by looking for the “RLA” rating on the data plate. Find all the parts you need for your Nordyne Furnace MGBB 056ABFC-06 at RepairClinic.com. %%EOF Parent Company: Nortek (formerly Nordyne … The third letter represents the product type. Example: SPCC-B504-A = 5.0 ton, Or TWS748A = 48,000 Btu = 4 ton Age: Through the seventies date of manufacture information is found as a number and a letter in the serial number where the number is the 0000004300 00000 n Why has the thermostat screen gone blank? 4-5 TON SERIES air conditioner pdf manual download. And this is another one that is 4 tons. Furnace, Air Conditioner user manuals, operating guides & specifications 0000003161 00000 n The six letter. Thank-You For Sharing. RLA is an acronym for Rated Load Amperage, and is what the maximum amperage should be when the condenser up and running. View and Download Nordyne 4-5 TON SERIES user's manual & installation instructions online. I can’t find it? In BTU, Ton P is voltage. Individual restrictors are available by part number - PN 664*** (where *** represents the size). © McGarry and Madsen, page for other related blog posts on this subject, or go to the. • Where is the air filter for my central air conditioner and furnace? 0 What are the most common problems with wall/window air conditioners? 30 = 2.5 tons. —18 = 1 ton —95 = 7.5 tons —21 = 1.5 tons —135 = 10 tons —26 = 2 tons —160 = 12.5 tons —28 = 2 tons —185 = 15 tons —31 = 2.5 tons —255 = 18.5 tons —41 = 3 tons —275 = 20 tons —46 = 3.5 tons —300 = 25 tons —51 = 4 tons —360 = 30 tons —65 = 5 tons —415 = 33 tons —81 = 6 tons —600 = 45 tons There cooling capacity figures also appear in model numbers … What's wrong? General Directions: (1) Locate the model number your researching. SEARCH BY MODEL NUMBER PARTS FINDER. Find the model number on your label. Quickly find the answers you need in our technical library. We offer a full line of Intertherm/Nordyne Mobile and Modular Home Electric Furnaces! Also, construction methods and materials vary in different parts of the country and it is possible that important issues related to your area may not be covered here. Here’s a rundown of the range you will encounter: 18 = 1.5 tons, 24 = 2 tons, 30 - 2.5 tons, 36 = 3 tons, 42 = 3.5 tons, 48 = 4 tons, and 60 = 5 tons. 0000000853 00000 n